High Purity Preparative Purification Enabled by UV/MS Trigger on LC-MS System

Seamless Purification for Drug Discovery with Screening, Preparative, and Purity check

Seamless Purification Workflow from Analytical to Preparative Using a Single Quad LC-MS System

OUR SERVICES

Let’s Research
More Science

Mass Directed Auto Purification (MDAP) System

Mass Directed Auto Purification (MDAP) System Request a Quote Spincotech

Mass-directed fractionation using MS molecular weight information ensures that target compounds are collected with a high degree of certainty. Furthermore, purity confirmation is possible by subjecting the fractions to LC-MS analysis. When large numbers of fractions are obtained, optimization of the purification / fractionation conditions can be conducted with greater efficiency through high-speed analysis. The highly acclaimed Nexera Prep System offering a wide choice of separation platforms [High Precision Analytical to Semi-Preparative (up to 10 mL/min), Semi-Preparative & Recycle Preparative (up to 20 mL/min) and large scale preparative purification (up to 150 mL/min)], ably supported by highly flexible fraction collector (up to 3240 test tubes) or combined unit that performs as autosampler for sample injection and fraction collector along with LCMS-2050 single quadrupole mass spectrometer offers an excellent choice for the Mass Directed Purification.

MS Signal Trigger - Recovery with No Target Fraction Omissions
As against the UV signal being used for fraction collection where compounds with low absorption can be overlooked, MS -based fractionation offers excellent sensitivity and selectivity with compounds having no UV absorption also being recovered.
With MS-based molecular weight as the criterion, selectivity for the target compounds is of the highest order.
MDAP Image one Spincotech
Purification of Un-separated Target Components
Two specific m/z values (from the target component and its impurity) were simultaneously used to obtain a “high-purity” fraction, even in the case of incomplete chromatographic separation.
Combine Detector Signals for High Purity Collection Spincotech
Flow Splitter for Fractionation Triggered by LC/MS Signals
If an LC–MS system is used as a preparative purification trigger, the column outflow is split to use only a portion of the flow as input to the LC–MS system. Column outflows can be split reliably by using an easy-to-install dedicated flow splitter.
Flow Splitter for Fractionation Triggered by LCMS Signals Spincotech

LCMS-2050, a powerful tool for even large molecular weight compounds such as oligonucleotides, peptides, proteins, polymers apart from low-molecular weight compounds is ideally suited for mass-based purification. With its heated ion source coupled with DUIS ionization involving both ESI & APCI techniques, it provides excellent sensitivity for compounds of diverse polarities and chemistries. Thanks to the UFscanning (15,000 u/sec) and UFswitching (10 msec) it enables high speed analysis for establishing the MS-based triggers for purification with a high degree of confidence.