Shimadzu LC Driver for OpenLab CDS

Shimadzu LC Driver for OpenLab CDS

Shimadzu LC Driver for OpenLab CDS Spincotech
Control of Shimadzu’s Nexera and i-Series series by OpenLab CDS is available by adoption of Agilent’s RC. Net driver standard. Adaptive Software:
  • OpenLab CDS
  • OpenLab EZChrom
Adaptive Software Spincotech

Features

Seamless control of Shimadzu LC

Shimadzu LC control parameters are set through the Instrument Setup embedded in the OpenLab software. These parameters are stored and are handled as standard OpenLab method files so that the instruments are directly controlled by OpenLab.
  • Solvent blending
  • Autosampler pretreatment program and overlap injection
  • Maximum of 4 oven control
  • Fluorescence 4-channel wavelength mode
  • System check
  • AutoPurge
  • Photo diode array 2D-channnel mode and 200Hz fast sampling
Instrument Setup screen Spincotech

Digital Data Acquisition For Enhanced Reliability

In addition to seamless system control, the detector signal is digitally transmitted to the data system. This eliminates the necessity to add an A/D converter for analogue data acquisition, making system validation easier and more robust. Furthermore, system status information, such as pump pressures and column oven temperature, may be monitored and recorded along with chromatograms, making your analytical data even more reliable.

Regulatory Compliance Support

Full system control, including autosampler control, uses OpenLab CDS Method File, and data processing is integrated with OpenLab CDS software so that the audit trail functions of OpenLab CDS software are fully utilized. This gives you full confidence in the compliance of the system to regulations such as GLP/GMP and US FDA 21 CFR Part 11.

Nexera Series Driver

Supporting for Nexera XS inert and Nexera lite inert
It is now possible to control of Nexera XS inert (LC-40D XSi and SIL-40C XSi) and Nexera lite inert (LC-40i and SIL-20A/SIL-20AC) for “Shimadzu UHPLC Nexera series” through OpenLab CDS and OpenLab EZChrom. OpenLab can be used to experience the advanced features of the Nexera series, such as “Bio-inert system that aims to suppress metal adsorption of the sample configured the sample flow path with non-metal.
  • Nexera XS inert
  • Nexera lite inert
Prevent Mistakes Caused By Running Out Of Mobile Phase

Using the MPM-40 mobile phase monitor*, it is possible to check levels of mobile phase, autosampler rinse solution etc. in real time (up to 12 bottles). Remaining volumes can be monitored from the Instrument status or from a smart device. You can receive advance notifications to your PC or smart device if the mobile phase is likely to become depleted, preventing costly mistakes in analysis.

Prevent Mistakes Caused By Running Out Of Mobile Phase Spincotech
Automated Pretreatment Programs Save Labor And Increase Reliability

A range of pretreatment programs for the SIL-40 series includes functions for dilution, addition, co-injection, etc. Automation prevents human error and increases repeatability as well as improving overall workflow efficiency.

Automated Pretreatment Programs Save Labor And Increase Reliability Spincotech