GC Columns and Consumables

GC Columns and Consumables

GC Columns and Consumables Spincotech

A wide range of GC Columns including Fused Silica Capillary Columns, Fused Silica PLOT Columns, Stainless Steel Columns, Guard Columns and application specific columns are offered for use GC/GC-MS. Shimadzu SH series are manufactured to the highest industry standard and designed to provide excellent chromatographic performance, reproducibility and long lifetime.

Stationary Phase100% dimethyl polysiloxane** % diphenyl / ** % dimethyl polysiloxane** % cyanopropylphenyl / ** % dimethyl polysiloxaneTrifluoropropyl methyl polysiloxanePolyethylene glycol
PolarityNon-polarLow to MediumMediumMedium to HighHigh
Separation PropertiesElution in boiling point orderAromatic compounds are retained by phenyl group contentEffective for separation of oxygenated compounds, isomers, etc.Uniquely retains compounds containing halogensStrong retention of polar compounds
ApplicationsGasoline and solvent relatedFlavors, environmental related, aromatic compounds, semivolatilesPesticides, PCBs, oxygenated compoundsHalogenated compounds, polar compounds, solventsPolar compounds, solvents, Flavors, FAME
ColumnsSH-I-1MS
SH-I-1HT
SH-1
SH-MetalX-1
SH-I-5MS
SH-I-5HT
SH-I-17
SH-I-5X
SH-5
SH-5MS
SH-20
SH-35
SH-35MS
SH-65
SH-MetalX-5
SH-1301
SH-624
SH-1701
SH-200
SH-200MS
SH-Wax
SH-PolarWax
SH-1, General Purpose Capillary Columns

Long life, durable capillary columns for routine analysis.  Available in narrow-bore and wide bore configurations with film thickness in the range 0.10 µm to 7.0 µm and typical columns lengths from 10 to 105 m

  • Non-polar phase: Crossbond™ 100% dimethyl polysiloxane
  • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates.
  • Equivalent to USP G1, G2, G38 phases.
  • Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1
SH-1 GC Columns and Consumables Spincotech
SH-5, General Purpose Capillary Columns

An excellent choice for many routine applications. Available with column IDs – 0.25 mm to 0.53 mm and film thickness of 0.1 µm 5.0 µm

  • Low-polarity phase: Crossbondx™ 5% diphenyl / 95% dimethyl polysiloxane
  • General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles.
  • Equivalent to USP G27 and G36 phases.
  • Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5
SH-5 GC Columns and Consumables Spincotech
SH-624, General Purpose Capillary Columns

Stable performance, long life columns for diverse applications.  Available in the range :  0.1 – 0.53 mm ID, 0.5 – 3.0 µm film thickness and lengths up to 105 m.

  • Mid-polarity phase: Crossbond™ 6% cyanopropylphenyl / 94% dimethyl polysiloxane
  • Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants.
  • Equivalent to USP G43 phase.
  • Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301
SH-624 GC Columns and Consumables Spincotech
SH-1701, General Purpose Capillary Columns

Highly stable performance in the analysis of many compounds.  Available from 0.18 mm to 0.53 mm ID, 0.1µm to 3. 0 µm.

  • Mid-polarity phase: Crossbond™ 14% cyanopropylphenyl / 86% dimethyl polysiloxane
  • General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), pesticides, and fragrance compounds.
  • Equivalent to USP G46 phase.
  • Similar phases: DB-1701P, DB-1701, CP Sil 19 CB, VF-1701ms, VF-1701 Pesticides, SPB-1701
SH-1701 GC Columns and Consumables Spincotech
SH-1701, General Purpose Capillary Columns Chromatography Spincotech
SH-WAX, Polyethylene Glycol Capillary Columns

Highly stable columns with up to 250 Deg C operations.  Available from 0.1- 1.0 µm film thickness, 0.1 to 0.53 mm ID and lengths up to 60m.

  • Polar phase: Crossbond™ polyethylene glycol
  • Best polyethylene glycol (PEG) phase for alkenols, glycols, and aldehydes.
  • Equivalent to USP G14, G15, G16, G20, G39 phases.
  • Similar phases: DB-Wax, CP-Wax 52 CB
SH-Wax Columns and Consumables Spincotech
SH-WAX Chromatography Spincotech
SH-I-1MS Capillary Columns

High-Performance Columns for a diverse applications.  Available in both narrow-bore and wide-bore configurations with film thickness ranging from 0.15 µm to 4.0 µm.

  • Non-polar phase: Crossbond™ 100% dimethyl polysiloxane
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g., Aroclor mixes), sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
  • Equivalent to USP G2 phase.
  • Similar phases: HP-1ms UI, HP-1ms, DB-1ms UI, DB-1ms, Ultra-1, VF-1ms, SPB-1, Equity-1
SH-I-1MS Columns and Consumables Spincotech
SH-I-1MS Capillary Columns Columns and Consumables
SH-I-5MS Capillary Columns

High-Performance Columns in both narrow-bore and wide-bore configurations with film thickness ranging from 0.1 to 1.5 µm.

  • Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • General-purpose columns for semi-volatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g., Aroclor mixes), solvent impurities.
  • Equivalent to USP G27 and G36 phases.
  • Similar phases: HP-5ms UI, HP-5ms, DB-5, Ultra-2, CP Sil 8 CB, SPB-5, Equity-5
SH-I-5MS Columns and Consumables Spincotech
SH-I-5MS Capillary Columns Chromatography Spincotech
SH-I-5Sil MS Capillary Columns

High-Performance Columns in both narrow-bore and wide-bore configurations with film thickness ranging from 0.10 to 2.0 µm.

  • Low-polarity phase: Crossbond™ silarylene phase 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane
  • Engineered to be a low-bleed GCMS column.
  • Excellent inertness for active compounds.
  • General-purpose columns—ideal for GCMS analysis of semi-volatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons.
  • Similar phases: DB-5ms UI, DB-5ms, VF-5ms, SLB-5ms
SH-I-5Sil MS Capillary ColumnsColumns and Consumables Spincotech
Gas Filters for Capillary GCs

These filters can purify supplied gas to 99.9999 % or higher purity levels by adsorbing and removing impurities (such as organic components, moisture, and oxygen) in the gas. They can help reduce analytical instrument downtime by preventing column deterioration due to oxygen, preventing ghost peaks and baseline fluctuations, eliminating excessive detector noise, and so on.

Gas Filters for Capillary GCs Chromatography Spincotech
Gas Filters for Capillary GCs Chromatography Spincotech 1
ClickTek Nuts and Ferrules for Capillary Columns

These parts enable easy tool-free connection/disconnection for compatible sample injection units and detectors. They are not oxygen permeable, will not generate debris, and will not adhere to the sample injection unit or detector. Use them at temperatures up to 350 °C.

ClickTek Nuts Chromatography Spincotech