A wide range of GC Columns including Fused Silica Capillary Columns, Fused Silica PLOT Columns, Stainless Steel Columns, Guard Columns and application specific columns are offered for use GC/GC-MS. Shimadzu SH series are manufactured to the highest industry standard and designed to provide excellent chromatographic performance, reproducibility and long lifetime.
| Stationary Phase | 100% dimethyl polysiloxane | ** % diphenyl / ** % dimethyl polysiloxane | ** % cyanopropylphenyl / ** % dimethyl polysiloxane | Trifluoropropyl methyl polysiloxane | Polyethylene glycol |
|---|---|---|---|---|---|
| Polarity | Non-polar | Low to Medium | Medium | Medium to High | High |
| Separation Properties | Elution in boiling point order | Aromatic compounds are retained by phenyl group content | Effective for separation of oxygenated compounds, isomers, etc. | Uniquely retains compounds containing halogens | Strong retention of polar compounds |
| Applications | Gasoline and solvent related | Flavors, environmental related, aromatic compounds, semivolatiles | Pesticides, PCBs, oxygenated compounds | Halogenated compounds, polar compounds, solvents | Polar compounds, solvents, Flavors, FAME |
| Columns | SH-I-1MS SH-I-1HT SH-1 SH-MetalX-1 | SH-I-5MS SH-I-5HT SH-I-17 SH-I-5X SH-5 SH-5MS SH-20 SH-35 SH-35MS SH-65 SH-MetalX-5 | SH-1301 SH-624 SH-1701 | SH-200 SH-200MS | SH-Wax SH-PolarWax |
Long life, durable capillary columns for routine analysis. Available in narrow-bore and wide bore configurations with film thickness in the range 0.10 µm to 7.0 µm and typical columns lengths from 10 to 105 m
An excellent choice for many routine applications. Available with column IDs – 0.25 mm to 0.53 mm and film thickness of 0.1 µm 5.0 µm
Stable performance, long life columns for diverse applications. Available in the range : 0.1 – 0.53 mm ID, 0.5 – 3.0 µm film thickness and lengths up to 105 m.
Highly stable performance in the analysis of many compounds. Available from 0.18 mm to 0.53 mm ID, 0.1µm to 3. 0 µm.
Highly stable columns with up to 250 Deg C operations. Available from 0.1- 1.0 µm film thickness, 0.1 to 0.53 mm ID and lengths up to 60m.
High-Performance Columns for a diverse applications. Available in both narrow-bore and wide-bore configurations with film thickness ranging from 0.15 µm to 4.0 µm.
High-Performance Columns in both narrow-bore and wide-bore configurations with film thickness ranging from 0.1 to 1.5 µm.
High-Performance Columns in both narrow-bore and wide-bore configurations with film thickness ranging from 0.10 to 2.0 µm.
These filters can purify supplied gas to 99.9999 % or higher purity levels by adsorbing and removing impurities (such as organic components, moisture, and oxygen) in the gas. They can help reduce analytical instrument downtime by preventing column deterioration due to oxygen, preventing ghost peaks and baseline fluctuations, eliminating excessive detector noise, and so on.
These parts enable easy tool-free connection/disconnection for compatible sample injection units and detectors. They are not oxygen permeable, will not generate debris, and will not adhere to the sample injection unit or detector. Use them at temperatures up to 350 °C.