Product

Brochure

OUR SERVICES

Let’s Research
More Science

SamuxMP

SamuxMP Spincotech
Rapid analysis of full, partial, and empty ratios for AAV development through manufacturing and QC release.

Simple, Rapid AAV Characterization

The Refeyn SamuxMP is a mass photometer optimized for adeno-associated virus (AAV) characterization and is an essential analytical tool for laboratories working with AAVs. SamuxMP mass photometry measurements are quick and require very little sample.

The SamuxMP precisely measures the empty/full capsid ratio for AAVs of any serotype as well as the quantities of partially filled and overfilled capsids. It can also detect impurities and aggregation, and give a rough capsid titer estimate as part of the standard data analysis procedure.

  • Quantitative characterization of AAVs of all serotypes
  • Easy measurement of empty/full ratio of AAV capsids
  • Rapid analysis requiring minimal sample
  • User-friendly operation
SamuxMP contact us bg image

Characterization of AAV Samples​

1. Empty/full AAV ratio measurement
2. Serotype-independent analysis
3. Partially filled and overfilled capsid quantification
4. Rough estimation of titer

Rapid Analysis Requiring Little Sample​

1. < 5 minutes to result
2. Little sample needed
3. Minimal sample preparation
4. Very low operating costs

User Friendly Operation​

1. User training < 1 day
2. Software customized for AAV analysis
3. Benchtop instrument, easy decontamination

Transformative AAV Analytics

Mass photometry is a bioanalytical technology that measures the mass of individual AAV particles in solution, quickly and using small amounts of sample.

Mass photometry is ideally suited for measurements of empty/full capsid ratios. Filled AAV capsids have greater mass than empty capsids, so they can be readily distinguished from empty capsids on mass photometry histograms (Fig 1).

Figure 1 Mass photometry measurement of AAV capsids (AAVDJ serotype) with SamuxMP. Two distinct peaks are visible: one with lower mass corresponding to empty capsids, and a second with higher mass corresponding to full capsids.

AAV-empty-full-resolution-transparent-background-Spincotech
Serotype-Agnostic AAV Analytics

The SamuxMP mass photometer can measure AAV capsids of any serotype without the need for protocol adjustments.

​Figure 2 shows SamuxMP measurements of empty AAV capsids of four different AAV serotypes.

​For each sample, the mass photometry measurements with the SamuxMP revealed a single, symmetric peak at the expected mass, confirming that the SamuxMP produces consistent results across serotypes.

Figure 2 Mass photometry measurements of empty AAV capsids of different serotypes on the SamuxMP. Mass histograms for four different AAV serotypes, with the mass and standard deviation calculated from three technical replicates.

Two-MP-3-DNA-protein-interactions-Spincotech-Image (1)

SamuxMP Software Package For GMP

Protein Oligomerization

This software solution expands the use of the SamuxMP and the SamuxMP Auto mass photometers to GMP – regulated environments and enables their use within AAV-based gene therapy manufacturing.

The software package supports compliance with the FDA 21 CFR 11 (US) and EU GMP Annex 11 regulations. It includes three applications: ManageMP, AcquireMP and EvaluateMPS.

The Refeyn service teams also provide installation and operational qualifications (IQ/OQ), as well as documentation and on-site training.

Refeyn-gmp-compliance_-for-PR_edited-Spincotech-Image