Nexis™ GC-2030

Nexis™ GC-2030 Spincotech

The Next Industry Standard Gas Chromatograph

Nexis™ GC-2030 offers best-in-class sensitivity, wide choice of injectors, high degree of automation and a fully compliant software for data integrity and traceability. Advanced flow controller (AFC)supports carrier gas constant linear velocity control, constant flowrate control, constant pressure control enabling ultra-high-speed and ultra-high-precision analyses. Tool-free Column Installation and One-Touch Inlet Maintenance of the injection port are enabled through the ClickTek™ connectors and ClickTek lever respectively, eliminating the need for cumbersome tools. Clean Pilot function conditions GC columns automatically, leading to more stable analytical results. With the carrier gas saver function, 90% reduction in helium can be achieved.

Delivers the Best Performance Spincotech
Delivers best performance
Achieves Exceptional Reproducibility Spincotech
Exceptional Reproducibility
  • Universal GC with three Flow control modes
  • Exceptional versatility & productivity
  • World’s highest FID sensitivity 1.2 pgC/s (dodecane)
  • Hydrogen sensor for additional safety.
  • Self-diagnostics and automatic notifications
  • Remote operations & Monitoring
  • Compliant with ER/S, 21 CFR Part 11 Guidelines
ClickTek™ Tool free column installation Spincotech
Tool-free column installation
One-touch Inlet Maintenance Spincotech
One-touch Inlet Maintenance

Nexis GC-2030 / HS-20 Headspace sampler, is an excellent choice for the analysis of residual solvents in pharmaceuticals as per USP General Chapters <467>. AOC-30 auto injector enables continuous analysis with a high accuracy and is equipped with Pre-treatment capabilities and overlapping injection functions. The system suitability check function automatically analyzes a standard sample and determines whether to proceed to the analysis of actual samples based on pre-set criteria. Apart from the high-sensitivity FID, other high-sensitivity detectors supporting diverse applications are : Barrier Discharge Ionization Detector (BID) for universal detection of all compounds, Flame Photometric Detector (FPD) for phosphorus and sulphur compounds, Electron Capture Detector (ECD) for electrophilic compounds, Flame Thermionic Detector (FTD) for nitrogen and phosphorus compounds. Variety of inlets – Split/Splitless injector for routine analysis, Direct Injection for split-less modes, On-column Injection for high-boiling compounds, Programmed Temperature Vaporization Injector for labile compounds further expand the range of applications.