Brevis™ GC-2050

Smaller, simpler, and easier to use – without compromising performance

The Brevis GC-2050 gas chromatograph delivers uncompromising analytical performance in a modern yet rugged design, easily meeting the analysis needs of laboratories in a range of industries such as petrochemistry, food products, environment, pharmaceuticals, and more.​

​ It achieves a space-saving width of only 350 mm and can double productivity by simultaneously analyzing samples on two analytical lines. Maintenance made easy with functions such as one-touch inlet, fast inlet maintenance, Easy sTop, and tool-less column installation. Additionally, this system reduces power consumption by about 30% compared to conventional models. It also minimizes helium gas use and supports alternative carrier gases.

Compact without Compromise

Space-saving yet expandable design

The compact Brevis GC-2050, with a 350 mm system width, including an auto-injector (AOC™-30i), makes even more use of lab space. Compared to the flagship Nexis™ GC-2030, the system’s width has been reduced by approximately 35 %. At the same time, it is possible to connect additional headspace samplers, a mass spectrometer, and other accessories (available soon), providing the scalability to cover the analytical needs of today’s GC/GCMS users.

Sufficient GC oven size

Despite its space-saving design, this GC oven does not require a dedicated column, and up to two general capillary columns can be used.

Remote Display

Even without a monitor on the Brevis GC-2050, you can use the GC Remote Display installed on a PC or tablet to monitor the device status and perform operations.Note: Only one Remote Display can be connected to a single GC at a time.
Connection Method: LAN / USB cable.

Compact and easy to maintain

①One-touch inlet maintenance

The injection port can be opened or closed without tools by simply sliding the ClickTek™ Nut lever. Replace the insert, slide the lever, and feel the click to ensure leak-free performance.

 

②Fast inlet maintenance, Easy sTop

Clicking the Maint. (Maintenance) button on the GC front will start lowering the temperature of the GC inlet and oven, and stop the gas supply automatically*. After maintenance of the inlet, clicking the button again will return the instrument to standby after an automatic leak check. Routine maintenance procedures can be further simplified.

Note: Disabling the automatic gas supply shutdown to protect the MS detector is possible.

Fast inlet maintenance, Easy sTop

 

③Tool-less column installation

The ClickTek makes column attachment a one-touch operation. A noticeable clicking sensation signals a secure column connection, putting the user at ease.

Note: The ClickTek connector is optional.

Category: