Advanced i-Series High Performance Liquid Chromatograph
Nexera XS inert Bio-inert UHPLC
Advanced i-Series Gel Permeation Chromatograph
N-Series, The NextGen UHPLC
Method Scouting System
Amino Acid Analysis System
Nexera Organic Acid Analysis System
Nexera Voglibose Analysis System
Nexera™ FV
P-Series All Round HPLC
Liquid Chromatography-Analytical
Detectors
SEDEX 85LT Low-Temperature Evaporative Light Scattering Detector for HPLC
SEDEX LT-ELSD LC Low-Temperature Evaporative Light-Scattering Detector
Sedex LT-ELSD Model 100 LT Universal Detector for HPLC
Beta-RAM Model 6 World’s leading Radio-HPLC Flow Detector
Flow-RAM Radio HPLC Detector
Scan-RAM radio-TLC
DECADE Elite Electrochemical Detector
Fluorescence Detector
Photodiode Array Detector
Refractive Index Detector
Onyx PCX Post-Column
Derivatization Instrument for HPLC
Vector PCX Postcolumn
Derivatization System
UVE™ Photochemical Reactor
Nexera XS inert Bio-inert UHPLC
The Nexera XS inert UHPLC offers the ideal solution for the separation of biomolecules using SEC, IEX, and HIC chromatography modes by combining the elevated pressure tolerance of a UHPLC system with complete inertness of the sample flow path, ensured by the absence of wetted metal surfaces and offering ultra-high resistance to corrosion, caused by mobile phases with high salt concentrations and extreme pH values. The same outstanding instrument performance capabilities offered by N-Series systems are also available in Nexera XS inert systems. For more advanced analysis, Nexera XS inert can be used with Analytical Intelligence technology for automatic analysis, analytical method development using method scouting, quality control on biologics etc.
Full-Range of Bio-Inert UHPLC Capabilities
For the quantitative analysis of biomolecules, particularly when high sensitivity is required, the adsorption of the target compound to a metal surface can result in a dramatic decrease in sensitivity. The Nexera XS inert system prevents peak tailing and sensitivity loss by eliminating adsorption of proteins, nucleic acids, and other components to metal surfaces. As a result, reliable and accurate quantitation is possible, even for low-concentration samples.
The Nexera XS inert system is equipped with unique technology that ensures the complete inertness of the sample flow path providing excellent peak shape and unsurpassed chromatographic separation.
The Nexera XS inert system is equipped with unique technology that ensures the complete inertness of the sample flow path providing excellent peak shape and unsurpassed chromatographic separation.
Flow Channel Switching Valves for Metal-absorbing Compounds
All valves used in Nexera XS inert systems are designed to inhibit metal adsorption. That ensures worry-free switching between multiple columns for method development or even for trap-and-elute analysis without being concerned about adsorption.
Mobile Phase pH Monitor (pHM-40) (optional)
In the case of Ion-exchange chromatography or size-exclusion chromatography used for the analysis of proteins or other biomolecules, the mobile phase pH can strongly affect chromatographic separation. The pH monitor pHM-40 continuously monitors the pH of mobile phases to identify any changes in mobile phase pH in real time.
Analytical Columns for Target Compounds
Analyzing biomolecules, such as proteins and nucleic acids, requires using columns intended for a variety of separation modes. In particular, samples sensitive to metal ions require a column that is optimized to reduce adsorption. Shimadzu offers columns optimized for a wide variety of molecules.