Boost your high sensitivity measurements over a wide wavelength range. The SPD-M40 has great accuracy in identification of compounds from absorbance spectra and performs an impurity check on all peaks. The industry leading i-PDeA deconvolution algorithm spectrally resolves coeluting peaks. The newly designed optical system guarantees both a wide linearity range and a superb signal-to-noise ratio performance at the same time. It has improved stability in analysis through flow cell/polychromator/lamp compartment temperature control. Each SPD-M40 is equipped with a UV cutoff filter, which allows even less variation and more robust analysis by minimizing sample decomposition.

Request a Quote

Intelligent Peak Deconvolution Analysis (i-PDeA) is a data analysis technique that extracts a single peak from co-eluted peaks and quantitates it by exploiting the differences in spectra between each compound. i-PDeA II enables users to visualize and detect a minor single impurity even when the impurity is co-eluted with an analyte. It also facilitates the separation of hard-to-separate peaks on the column through computer processing and deconvolution of the spectrum information, which reduces the effort required to investigate separation parameters.

  • Wavelength range of 190 nm – 800 nm, wavelength accuracy ± 1 nm, noise level of 4.5 x 10-6 AU, and drift less than 0.4 x 10-3 AU/hour.
  • Contains both a deuterium (D2) and tungsten (W) lamp.
  • UV cut-off filter that removes wavelengths below 240 nm from entering the flow cell.
  • Has a 1024 element diode array. Fully temperature-controlled optics, including the optical bench, lamp housing, and flow cell. Monitored and controlled with a standard web browser.
  • Built-in Cell ID that is automatically recorded in analysis data.
  • Linear up to 2.5 AU (ASTM method). Pressure tolerance of 12 MPa.
  • Automatic wavelength accuracy check and wavelength correction.
  • Integrated 4 channel analog output.
  • Optional flow cells that can be changed by the user: UHPLC, semi-micro, inert, preparative and high-pressure cell.
  • Capable of using the i-PDeA II deconvolution algorithm to resolve co-eluting peaks.

When you apply i-PDeA, you can selectively visualize only the components you want to view, even peaks that are not separated!

Even though the difference in absorption wavelength between 1,2-dimethoxybenzene (274.2 nm wavelength) and 1,3-dimethoxybenzene (273.6 nm) is only 0.6 nm, the individual chromatograms can be obtained!