Advanced i-Series High Performance Liquid Chromatograph
Nexera XS inert Bio-inert UHPLC
Advanced i-Series Gel Permeation Chromatograph
N-Series, The NextGen UHPLC
Method Scouting System
Amino Acid Analysis System
Nexera Organic Acid Analysis System
Nexera Voglibose Analysis System
Nexera™ FV
P-Series All Round HPLC
Liquid Chromatography-Analytical
Detectors
SEDEX 85LT Low-Temperature Evaporative Light Scattering Detector for HPLC
SEDEX LT-ELSD LC Low-Temperature Evaporative Light-Scattering Detector
Sedex LT-ELSD Model 100 LT Universal Detector for HPLC
Beta-RAM Model 6 World’s leading Radio-HPLC Flow Detector
Flow-RAM Radio HPLC Detector
Scan-RAM radio-TLC
DECADE Elite Electrochemical Detector
Fluorescence Detector
Photodiode Array Detector
Refractive Index Detector
Onyx PCX Post-Column
Derivatization Instrument for HPLC
Vector PCX Postcolumn
Derivatization System
UVE™ Photochemical Reactor
Smaller, simpler, and easier to use – without compromising performance
The Brevis GC-2050 gas chromatograph delivers uncompromising analytical performance in a modern yet rugged design, easily meeting the analysis needs of laboratories in a range of industries such as petrochemistry, food products, environment, pharmaceuticals, and more.
It achieves a space-saving width of only 350 mm and can double productivity by simultaneously analyzing samples on two analytical lines. Maintenance made easy with functions such as one-touch inlet, fast inlet maintenance, Easy sTop, and tool-less column installation. Additionally, this system reduces power consumption by about 30% compared to conventional models. It also minimizes helium gas use and supports alternative carrier gases.
Compact without Compromise
Space-saving yet expandable design
Sufficient GC oven size
Remote Display
Even without a monitor on the Brevis GC-2050, you can use the GC Remote Display installed on a PC or tablet to monitor the device status and perform operations.Note: Only one Remote Display can be connected to a single GC at a time.
Connection Method: LAN / USB cable.
Compact and easy to maintain
①One-touch inlet maintenance
The injection port can be opened or closed without tools by simply sliding the ClickTek™ Nut lever. Replace the insert, slide the lever, and feel the click to ensure leak-free performance.
②Fast inlet maintenance, Easy Stop
Clicking the Maint. (Maintenance) button on the GC front will start lowering the temperature of the GC inlet and oven, and stop the gas supply automatically*. After maintenance of the inlet, clicking the button again will return the instrument to standby after an automatic leak check. Routine maintenance procedures can be further simplified.
Note: Disabling the automatic gas supply shutdown to protect the MS detector is possible.
③Tool-less column installation
The ClickTek makes column attachment a one-touch operation. A noticeable clicking sensation signals a secure column connection, putting the user at ease.
Note: The ClickTek connector is optional.